Electronics Era

  • About Us
  • Advertise with Us
  • Contact Us
  • e-Mag
  • Webinars
Header logo on website
Advertisement
Advertisement
Menu
  • Home
  • News
    • Industry News
    • Product News
  • TECH ROOM
    • Sensor
    • VR / AR
    • Embedded
    • Medical Electronics
    • Industry 4.0
    • Robotic
    • Automation
    • Smart Machine
    • Component
    • MCU
    • Manufacturing
    • Aerospace & Defence
    • Security
    • Policy
    • RENEWABLES
      • Sustainability
  • Semiconductor
    • AUTOMOTIVE ELECTRONICS
      • EVs
      • HEVs
      • ADAS
      • Connected Cars
    • IoT-Internet of Things
      • Development Kit
      • IoT Design
    • Power Electronics
      • AC-DC/DC-DC Converters
      • Mosfets
      • IGBTs
      • LEDs
  • T & M
    • 5G testing
    • Oscilloscopes
    • SDN & NFV
    • RF & Wireless
  • AI/ML
  • Telecom
    • 5G/6G
  • Future Tech
    • Data Center
    • Cloud Computing
    • Big Data Analytics
  • Webinars
  • Editor’s Pick
    • Tech Article
    • Tech Blog
    • White Papers
    • EE-Tech Talk
    • Market Research
    • Videos
  • EE Awards
    • EE Awards 2025
    • EE Awards 2024
  • MORE
    • E-Mag
    • Events
    • MAGAZINE Subscription
    • Contact Us
Home Future Tech Data Center

Grid-Ready Data Centres

How high-resistance grounding keeps data centres online

Nimish by Nimish
February 11, 2026
in Data Center
Reading Time: 6 mins read
Cressall Resistors

data centres

Share on FacebookShare on TwitterShare on LinkedIn

In December 2025, the UK’s National Energy System Operator (NESO) announced the results of its major overhaul of the UK’s grid connection process, removing speculative schemes and introducing a readiness-based system. While this affects all electricity projects, it raises the bar for data centres, which must now demonstrate grid‑friendly behaviour from day one. Here, Mike Torbitt, managing director of resistor manufacturer Cressall Resistors, explains how neutral earthing resistors (NERs) support resilient, grid‑compatible operation.

Data centres have been recognised as Critical National Infrastructure (CNI) since September 2024, placing them on “an equal footing with water, energy and emergency services systems”. While this recognition is invaluable to scaling capacity, NESO’s reforms add a new layer of complexity.

The Connections Reform context

Under the Connections Reform, NESO now prioritises “first ready and needed,” replacing the former first‑come, first‑served approach. Many transmission-connected demand projects – including data centres – have been placed into firm capacity blocks with connection dates extending to 2035, reflecting a more realistic delivery timeline than the prior ambition to connect the full pipeline by 2030. In this context, fault management and predictable, grid‑friendly operation become prerequisites for connection.

The readiness framework is evidence‑based. To secure a firm offer, developers must prove deliverability and true grid readiness — not just on paper, but through design maturity, risk controls and credible delivery plans. A robust power and protection strategy is therefore critical, showing the facility will behave predictably during network disturbances and will not trigger unnecessary disconnections.

What is high-resistance grounding?

One mechanism central to grid‑friendly design is high‑resistance earthing, also known as high‑resistance grounding (HRG). Although industry benchmarking shows overall outages are declining, Uptime Institute data indicates power remains the leading cause of impactful incidents when failures do occur, cited by 54 per cent of operators surveyed would be more accurate to the Uptime Institute’s methodology.

In HRG systems, the transformer or generator neutral is connected to earth through a high‑value resistor. By introducing resistance, HRG limits single‑line‑to‑earth fault current to a small, controlled value — typically a few amps at low voltage or tens to hundreds of amps at medium voltage. The outcome is that a first earth fault becomes an alarm‑only event rather than an immediate trip, enabling continued operation while teams quickly locate and clear the fault.

This approach avoids the drawbacks of other schemes. Unlike solid earthing, it prevents very high single‑line‑to‑earth currents and the associated incident energy, and unlike ungrounded systems, it keeps the neutral referenced, suppressing transient overvoltages and making faults easier to locate.

Proper HRG design sets the resistor so the permitted fault current is above the system’s capacitive charging current, yet low enough to reduce equipment stress and arc flash energy for single-line-to-earth faults. In data centres, this keeps the first earth fault ‘alarm‑only’, sustaining critical services while teams rapidly pinpoint the faulted feeder, avoiding nuisance trips across uninterruptible power supply and generator transitions and supporting grid‑friendly operation in the high‑density, always‑on environment.

The critical component

An NER is the enabling component of a HRG system because it connects the neutral point to earth through a precisely selected resistance. By setting the resistance value correctly, the NER establishes the single‑line‑to‑earth fault current and the associated thermal duty so that protection relays can reliably detect a first fault without forcing an immediate trip. This behaviour keeps the system stable during disturbances and allows operators to locate and clear faults while maintaining service continuity.

For data centres, NERs must be engineered to match real‑world constraints such as footprint, access routes for installation and maintenance, cooling and ventilation needs, and compliance with relevant international electrical standards. Cressall’s designs prioritise ease of maintenance, high thermal performance and long service life so that facilities can run continuously and recover predictably after fault events or tests.

Selecting the right resistor element is central to performance and cost. Edge‑wound coils are suited to higher currents, while grid and wire-wound elements serve other ratings efficiently. Cressall manufactures NERs across essentially any system voltage and initial fault‑current requirement, with rated durations ranging from a few seconds to continuous duty, so that specifications can align with the site’s protection guidelines and operational objectives.

Now that grid connections have been reprioritised, well‑specified NERs within HRG schemes make the first earth fault a managed, alarm‑only condition, keeping services online, demonstrating grid‑friendly behaviour and helping ensure data centre designs do not delay connection.

Tags: Cressall Resistorsdata centres
Nimish

Nimish

[adrotate banner="216"]

Join Our Newsletter

* indicates required
Electronics Era

Electronics Era, India's no.1 growing B2B news forum on Electronics and Cutting Edge Technology is exploring the editorial opportunity for organizations working in the Electronics Manufacturing Services(EMS) Industry.

Follow Us

Browse by Category

  • 5G testing
  • 5G/6G
  • AC-DC/DC-DC Converters
  • ADAS
  • Aerospace & Defence
  • AI/ML
  • Automation
  • AUTOMOTIVE ELECTRONICS
  • Big Data Analytics
  • Blockchain
  • Cloud Computing
  • Component
  • Connected Cars
  • Data Center
  • Editor's Desk
  • EE-Tech Talk
  • Electronics Components
  • Embedded
  • EVs
  • Future Tech
  • HEVs
  • Industry 4.0
  • Industry News
  • IoT Design
  • IoT-Internet of Things
  • LED & Lighting
  • LEDs
  • Manufacturing
  • Market Research
  • MCU
  • Medical Electronics
  • Mosfets
  • News
  • Oscilloscopes
  • Policy
  • Power Electronics
  • Product News
  • RENEWABLES
  • RF & Wireless
  • Robotic
  • SDN & NFV
  • Security
  • Semiconductor
  • Sensor
  • Smart Machine
  • SMT/PCB/EMS
  • Sustainability
  • T & M
  • Tech Article
  • Tech Blog
  • TECH ROOM
  • Telecom
  • Uncategorized
  • VR / AR
  • White Papers

Recent News

Ingram Micro

Achievers World Honors Ingram Micro’s Sanjib Sahoo as Business Excellence Icon of the World

June 3, 2026
NeoCortec

NeoMesh from NeoCortec powers e-IoT platform from Endrich Bauelemente

June 3, 2026
  • About Us
  • Advertise with Us
  • Contact Us

© 2022-23 TechZone Print Media | All Rights Reserved

No Result
View All Result
  • Home
  • News
    • Industry News
    • Product News
  • TECH ROOM
    • Sensor
    • VR / AR
    • Embedded
    • Medical Electronics
    • Industry 4.0
    • Robotic
    • Automation
    • Smart Machine
    • Component
    • MCU
    • Manufacturing
    • Aerospace & Defence
    • Security
    • Policy
    • RENEWABLES
      • Sustainability
  • Semiconductor
    • AUTOMOTIVE ELECTRONICS
      • EVs
      • HEVs
      • ADAS
      • Connected Cars
    • IoT-Internet of Things
      • Development Kit
      • IoT Design
    • Power Electronics
      • AC-DC/DC-DC Converters
      • Mosfets
      • IGBTs
      • LEDs
  • T & M
    • 5G testing
    • Oscilloscopes
    • SDN & NFV
    • RF & Wireless
  • AI/ML
  • Telecom
    • 5G/6G
  • Future Tech
    • Data Center
    • Cloud Computing
    • Big Data Analytics
  • Webinars
  • Editor’s Pick
    • Tech Article
    • Tech Blog
    • White Papers
    • EE-Tech Talk
    • Market Research
    • Videos
  • EE Awards
    • EE Awards 2025
    • EE Awards 2024
  • MORE
    • E-Mag
    • Events
    • MAGAZINE Subscription
    • Contact Us

© 2022-23 TechZone Print Media | All Rights Reserved

Advertisement
Advertisement